1 par de electrodos de fibra para empalmador de fusión INNO IFS-15 IFS-15H IFS-10 View3 / 5/7
1 par de electrodos de fibra para empalmador de fusión INNO IFS-15 IFS-15H IFS-10 View3 / 5/7
$ 9,58
30% de descuento
$ 13,69
Sin impuestos
Product description:
100% brand new and high quality
Made of high-quality materials, durable
This rod is suitable for IFS-10, IFS-15 and IFS-15H.
View3,View5,View7
Number of discharges: 3000 times
Installation and maintenance
Electrode replacement method:
First of all, it is necessary to confirm that the welding machine is in a shutdown state,
Remove the protective cover of the electrode chamber and loosen
Fix the upper electrode and take out the upper Electrode. Then loosen the top
Wire the lower electrode and take out the lower Electrode.
Second, install new electrodes. The operation steps are reverse to the following methods
Disassemble the Electrode. You can operate in sequence. The difference between the two
The two electrode tips are required to be 2.6 /- 0.2 mm.
Finally, during the assembly process, do not touch the electrode tip
Prevent electrode damage, avoid electrode damage
Fall into the machine. After replacing the electrode, the arc position should be
Calibrated.
Electrode cleaning and arc calibration:
After installing the electrodes, turn on the power switch of the welder.
Carry out.
After the welder enters the initial screen, press the menu key to enter the first
Level menu.
Find the machine maintenance personnel by moving the cursor and enter the cleaning electrode
Items, after confirmation, the machine will automatically discharge cleaning and aging
Electrode.
Install the cut left/right fiber, find the arc position item by moving the fiber
Cursor and keep the position between three points and a single line optical
The tip of the fiber and the two electrodes pass the operation. The discharge test will be
It is carried out by the machine and can be adjusted according to the actual situation.
Finally, press the menu key and exit in turn.
Package list:
1 pair of fiber optic electrodes
Note:
1. The real color of the item may be slightly different from the pictures shown on website caused by many factors such as brightness of your monitor and light brightness.
2. Please allow slight manual measurement deviation for the data.
100% brand new and high quality
Made of high-quality materials, durable
This rod is suitable for IFS-10, IFS-15 and IFS-15H.
View3,View5,View7
Number of discharges: 3000 times
Installation and maintenance
Electrode replacement method:
First of all, it is necessary to confirm that the welding machine is in a shutdown state,
Remove the protective cover of the electrode chamber and loosen
Fix the upper electrode and take out the upper Electrode. Then loosen the top
Wire the lower electrode and take out the lower Electrode.
Second, install new electrodes. The operation steps are reverse to the following methods
Disassemble the Electrode. You can operate in sequence. The difference between the two
The two electrode tips are required to be 2.6 /- 0.2 mm.
Finally, during the assembly process, do not touch the electrode tip
Prevent electrode damage, avoid electrode damage
Fall into the machine. After replacing the electrode, the arc position should be
Calibrated.
Electrode cleaning and arc calibration:
After installing the electrodes, turn on the power switch of the welder.
Carry out.
After the welder enters the initial screen, press the menu key to enter the first
Level menu.
Find the machine maintenance personnel by moving the cursor and enter the cleaning electrode
Items, after confirmation, the machine will automatically discharge cleaning and aging
Electrode.
Install the cut left/right fiber, find the arc position item by moving the fiber
Cursor and keep the position between three points and a single line optical
The tip of the fiber and the two electrodes pass the operation. The discharge test will be
It is carried out by the machine and can be adjusted according to the actual situation.
Finally, press the menu key and exit in turn.
Package list:
1 pair of fiber optic electrodes
Note:
1. The real color of the item may be slightly different from the pictures shown on website caused by many factors such as brightness of your monitor and light brightness.
2. Please allow slight manual measurement deviation for the data.